Operating rules for electric gynecological operating table

News

During surgery, if there is no established system to maintain a sterile environment, sterilized items and surgical areas will remain contaminated, leading to wound infection, sometimes surgical failure, and even affecting the patient’s life. The electric gynecological operating table is particularly important. So, let’s learn about the operating rules of the electric gynecological operating table together!
There are the following operating rules for electric gynecological surgical beds:
1 When surgical personnel wash their hands, their arms must not come into contact with unsterilized items. After wearing sterile surgical gowns and gloves, bacterial areas are considered on the back, waist, and shoulders and must not be touched; Similarly, do not touch the fabric below the edge of the electric medical bed.

Electric gynecological operating table
2 Surgical personnel are not allowed to pass instruments and surgical supplies behind them. Sterile towels and instruments that fall outside the operating table should not be picked up and reused.
3 During surgery, if gloves are damaged or come into contact with areas with bacteria, sterile gloves must be replaced separately. If the forearm or elbow comes into contact with areas with bacteria, sterile surgical gowns or sleeves, sterile towels, cloth sheets, etc. must be replaced. The sterile isolation effect is not complete, and dry sterile sheets must be covered.
4 During surgery, if the surgeon on the same side needs to change positions, to prevent contamination, take a step back, turn around, and turn back-to-back to another position.
5 Before the surgery begins, it is necessary to count the instruments and dressings. At the end of the surgery, check the chest, abdomen and other body cavities to confirm that the number of instruments and dressings is correct. Then, close the incision to avoid foreign objects remaining in the cavity, which can seriously affect delivery.
6 Cover the edge of the incision with a large gauze pad or surgical towel, fix it with tissue forceps or sutures, and only expose the surgical incision.
7 Before cutting open and suturing the skin, wipe the solution clean with 70% alcohol or 0.1% chloroprene rubber, and then apply another layer of skin disinfection.
8 Before cutting open hollow organs, protect the surrounding tissues with gauze to prevent or reduce contamination.
9 Visitors are not allowed to get too close to the surgical personnel, nor too high. In addition, to reduce the chance of pollution, frequent indoor walking is not allowed.

Electric gynecological operating table。
The electric gynecological operating table, like traditional operating tables, is a basic medical device, characterized by the addition of electrical equipment, partition folding equipment, hydraulic auxiliary equipment, electrical control systems, etc. to traditional operating tables.
From a classification perspective, it can be divided into portable surgical tables, manual hydraulic transmission surgical tables, and electric surgical tables. Due to the high-risk nature of surgery and the usually tense atmosphere on site, the quality of electric surgical tables has a significant impact on doctors and patients. If there are quality problems with the operating table during surgery, it will inevitably bring serious psychological pressure to patients and doctors. At the same time, this also affects the hospital’s medical level and overall situation in the minds of patients. In large hospitals, doctors usually use highly automated electric operating tables. A first-class operating table is stable and durable, and the material of the electric gynecological operating table determines its quality.
High quality electric gynecological operating beds typically use new durable materials such as stainless steel and magnesium aluminum alloys. The body is partially covered with stainless steel, and the tabletop is made of high-strength acrylic sheet, which has anti fouling, anti-corrosion, heat resistance, and insulation effects, making it suitable for use on the operating table.
The above introduction is the operating rules of the electric gynecological operating table. If you need to learn more, please feel free to contact us at any time!


Post time: Nov-07-2024