Shadowless lamps are mainly used for medical lighting applications in operating rooms.
The essence that distinguishes it from ordinary lamps is to meet the special requirements of surgery:
1、 Operating room lighting brightness regulations
Surgical lamps can ensure the brightness of the operating room lighting, and the general surgeon in the operating room must be able to accurately distinguish the contour, color tone, and movement. Therefore, it is necessary to have a light compression intensity close to the quality of sunlight, at least 100000 light intensities.

Shadowless lamp。
2、 Safe surgical lighting
The surgical lamp can provide a single lamp with a brightness of up to 160000 light intensity, and the brightness of the surgical lamp can be adjusted infinitely. In case of common malfunctions during operation, the reserved light bulb can be switched on its own for 0.1 seconds, so the surgical lamp can provide reliable surgical illumination.
3、 The rule of no shadows
According to the multilateral cooperation reflector, the surgical lamp can achieve the rule of no black shadow illumination. This vertical surface is formed in one industrial production and stamping process, with a high return light rate of 95%, generating a same source of light. The light is generated from 80 cm below the lamp panel, reaching a depth of up to the surgical area, ensuring the brightness of the plastic surgery’s sunlight without black shadows. Moreover, when the surgeon’s shoulders, hands, and head cover a part of the lamp source, it can still maintain a very uniform shape.

4、 Cold light lamp regulations
The surgical lamp not only provides bright light but also prevents heat generation. The new filter of the surgical shadowless lamp can filter 99.5% of the infrared component, ensuring that only the cold light reaches the surgical area.
5、 Regulations on detachable disinfection and sterilization.
The appearance design and installation position of the surgical lamp, as well as the standardized sealing handle, can reasonably control the total number of pathogens and can be disassembled, disinfected, and sterilized.

Shadowless lamp
Common problems and maintenance:
1、 Daily inspection:
1. Bulb operation status (PRX6000 and 8000)
Method: Place a piece of white paper in the work area, and if there is a dark arc, replace the corresponding light bulb
2. Timely condition of disinfection and sterilization handle
Method: Several clicks during installation
clear:
1) Wipe the surface with a weakly alkaline solvent (soap solution)
2) Prevent the use of effective chlorine cleaning agents (to damage metal materials) and ethanol cleaning agents (to damage plastics and paints)
2、 Monthly inspection:
Mainly to verify if the backup power system software (rechargeable battery) is functioning properly
Method: Disconnect the 220V switch power supply and see if the backup power supply is running
3、 The average lifespan of a light bulb is 1000 hours:
For sockets, they are usually replaced once a year. The prerequisite is to use manufacturer specific light bulbs
4、 Annual review:
You can ask a professional manufacturer to send someone to inspect. Dismantling and replacing aging components